DC centrifugal compact fan (single-intake) -RLF35-8/12N

Short Description:

Protection against reverse polarity and blocked rotor.


Product Detail

Product Tags

FAQ

Technical Description

General description

Forward-curved impeller

Weight

0.040 kg

Dimensions

51 x 51 x 15 mm

Impeller material

glass-fiber reinforced plastic

Housing material

Scroll housing made of glass-fiber reinforced plastic.

Airflow direction

Axial intake, radial discharge from outlet.

Bearing

Ball bearing

Service life L10 at 40 °C

60000 h

Service life L10 at maximum temperature

30000 h

Cable

with leads AWG 26, TR 64

Motor protection

Protection against reverse polarity and blocked rotor.

Locked-rotor protection

electronic locked-rotor protection

Approval

CE

 

Nominal data

Type of voltage

 

DC

Nominal voltage

in V

12

Nominal voltage range

in V

8 .. 13,2

Speed

in min-1

6700

Power input

in W

3,5

Min. ambient temperature

in °C

-20

Max. ambient temperature

in °C

70

Air flow

in m³/h

9,6

Sound power level

in B

5,5

 

Curves

1

Drawing

2

Product Drawing

Introducing the DC centrifugal compact fan with a single-intake - the RLF35-8/12N. This innovative fan is ideal for use in a wide range of applications, including automotive, aerospace, medical, and industrial industries. It is designed to provide high-speed air movement with minimal noise, making it a popular choice for many different uses.

One of the key features of this fan is its forward-curved impeller, which ensures that it can move air quickly and efficiently. The impeller is designed to deliver a high amount of airflow in a compact unit. Its small size of 51 x 51 x 15 mm makes it perfect for use in applications where space is limited.

The fan has a high-performance motor that ensures efficient operation, low noise, and long service life. Its DC motor is designed to provide reliable performance in a wide range of conditions, making it a high-quality choice for any application. The fan also has low power consumption, meaning it is cost-effective and environmentally friendly.

Another feature of the RLF35-8/12N fan is its single-intake design, which allows it to be easily installed in tight spaces. It has an innovative air guide structure that directs airflow to achieve the best cooling effect. Additionally, the fan is equipped with a thermal DC cut-off function that protects the motor from overheating, ensuring maximum safety and reliability.

The fan is also easy to install and maintain, making it user-friendly and convenient. Its compact size means that it can be installed in a wide range of applications, and its innovative design ensures optimal performance with minimal downtime.

In summary, the RLF35-8/12N DC centrifugal compact fan with a single-intake is the perfect choice for any application that requires high-speed air movement, low noise, and efficient operation. Its small size, innovative design features, and high-quality construction make it a must-have for any industry. So, be sure to get your hands on the RLF35-8/12N fan today, and enjoy efficient cooling and low noise for your applications!


  • Previous:
  • Next:

  • What motors does Lianxing offer?
    Do you have a minimum order quantity?

    What’s the maximum voltage you can apply to a blower?
    The maximum voltage that can be applied to a fan motor varies from model to model, but is typically 5%-10% above the nominal voltage listed.  Consult the factory to determine the maximum voltage for a particular part number, and to learn more about the negative effects that high voltages might have on the motor

    What is a fan’s of voltage range?
    Ebmpapst EC fans are able to perform equally well across a range of input voltages. These fans will have the maximum and minimum acceptable voltages listed on the label, such as the one below:

     detail3 

    Note that in order to reach a desired performance point, the fan may need to draw additional current at low voltages.

    Can all 60 Hz blower motors operate on a frequency of 50 Hz?
    Not all ebmpapst fans are designed to operate at both 50 and 60 Hz. If a fan is able to accept both 50 Hz and 60 Hz power supplies, it will have a “50/60Hz” mark on its label, such as the one below:

     detail2

    Consult the factory if you intend to use a power supply with a frequency that does not match the recommended frequency of your fan.

    How is fan performance defined?

    When determining fan performance, several factors are taken into consideration. These factors primarily include: airflow, static pressure, operating points, RPM, power & current, and sound performance. Of these factors, ebmpapst presents a performance curve with our products to provide a quick-glance overview of the performance. Performance curves use just three of the aforementioned factors: airflow, static pressure, and operating points.

    What is Airflow?
    For the air-moving industry, it is important to know how quickly some volume of air is being displaced from one location to another, or, more simply stated, how much air is being moved in a set amount of time.

    Ebmpapst typically expresses airflow in Cubic Feet per Minute (CFM) or cubic meters per hour (m3/h).


    What is Static Pressure?
    Once again the air-moving industry is faced with another challenge, the resistance to flow. Static pressure, sometimes referred to as back pressure or system resistance, is a continuous force on the air (or gas) due to the resistance to flow. These resistances to flow can come from sources such as static air, turbulence and impedances within the system like filters or grills. A higher static pressure will cause a lower airflow, in the same way that a smaller pipe reduces the amount of water that can flow through it.

    Ebmpapst typically expresses static pressure in inches water gauge (in. W.G.) or Pascals (Pa).


    What is the System Operating Point?
    For any fan we can determine how much air it is able to move in a given amount of time (airflow) and how much static pressure it can overcome. For any given system, we can determine the amount of static pressure it will create at any given airflow.

    Taking these known values for airflow and static pressure, we can plot them on a two-dimensional chart. The operating point is the point at which the fan performance curve and the system resistance curve intersect. In real terms, it is the amount of airflow a given fan can move through a given system.


    How do I read an air performance curve?
    To aid in fan selection, ebmpapst provides an air performance graph with its products. The air performance graph consists of a series of curves that chart airflow against static pressure.

    Follow along on the chart below. The x-axis is for airflow, while the y-axis is for static pressure. The blue line ‘A’ illustrates the fan’s performance outside of a system. To find the operating point 900CFM @ 2 in.w.g., follow the x-axis to 900, then follow the y-axis up to 2 (Point ‘B’). Since this operating point ‘B’ is below the performance curve, it is a point that the fan can achieve.

    detail1

    Lines ‘C’, ‘D’, and ‘E’ are example system resistance curves – as airflow increases, the static pressure (or resistance to airflow) also increases, making it harder to move air. Typically, any point between the highest and lowest of our example resistance curves is the ideal operating range for the fan to achieve its highest efficiency. Some performance graphs will have multiple airflow curves; this would indicate that the fan is capable of multiple speeds in order to match operating points below its maximum speed, thus saving energy.

    What types of produces does ebmpapst make? What is each type best suited for ?

     Forward Curved Impellers

    detail4 

    • There are two types of forward curved impellers, dual and single inlet.
    • Used primarily in medium pressure, high flow applications.
    • Possible market uses: ventilation, refrigeration etc.

    Backward Curved Impellers

    detail5

    • Used primarily in high pressure, high flow applications.
    • Possible market uses: data center, general ventilation, agriculture; transportation etc.

    Axial Fans

    3

    • Used primarily in low pressure, high flow applications.
    • Possible market uses: LED, ventilation, agriculture; transportation, etc.
    Write your message here and send it to us