DC axial compact fan-4412 FGM
Technical Description
Weight |
0.170 kg |
Dimensions |
119 x 119 x 25 mm |
Impeller material |
Glass-fiber reinforced PA plastic |
Housing material |
Glass-fiber reinforced PBT plastic |
Airflow direction |
Exhaust over struts |
Direction of rotation |
Counterclockwise, viewed toward rotor |
Bearing |
Sintec sleeve bearing |
Service life L10 at 40 °C |
75000 h |
Service life L10 at maximum temperature |
27500 h |
Cable |
Leads AWG 24, TR 64, stripped and tin-plated. |
Motor protection |
Protection against reverse polarity and blocked rotor. |
Locked-rotor protection |
Locked-rotor and overload protection |
Approval |
VDE, CSA, UL, CE |
Option |
Speed signal |
Nominal data
Type of voltage |
|
DC |
Nominal voltage |
in V |
12 |
Nominal voltage range |
in V |
7 .. 12.6 |
Speed |
in min-1 |
2400 |
Power input |
in W |
3,2 |
Min. ambient temperature |
in °C |
-20 |
Max. ambient temperature |
in °C |
75 |
Air flow |
in m³/h |
140 |
Sound power level |
in B |
4,8 |
Sound pressure level |
in dB(A) |
38 |
Introducing
The DC axial compact fan 4412 FGM is powered by a DC motor and is able to provide high performance cooling while maintaining energy efficiency. This makes it an ideal solution for a variety of electronic and industrial equipment, including servers, power supplies, and other devices that require reliable thermal management.
DC Axial Compact Fan - 4412 One of the main features of the FGM is its compact design. Measuring just a few inches, this fan can easily fit into tight spaces without sacrificing performance. This makes it an excellent choice for space-constrained applications, allowing you to enjoy powerful cooling without taking up valuable space.
In addition to its compact dimensions, the DC axial compact fan 4412 FGM is designed for easy installation and maintenance. With its simple mounting system and durable construction, this fan can be quickly and easily integrated into your existing equipment, saving you time and effort during the installation process. Its rugged design also ensures long-term reliability, reducing the need for frequent maintenance and replacement.
The DC axial compact fan 4412 FGM is also designed for quiet operation, making it suitable for use in environments where noise levels must be kept to a minimum. Whether in a professional office environment or a sensitive industrial environment, this fan provides powerful cooling without unnecessary noise pollution.
In addition, the DC axial compact fan 4412 FGM is designed to withstand the harsh environment of continuous operation. Its durable construction and high-quality materials ensure reliable operation even in demanding conditions, making it a reliable choice for critical applications requiring cooling.
Combining compact size, efficient cooling and reliable performance, the DC Axial Compact Fan 4412 FGM is the perfect solution for your electronic and industrial cooling needs. Whether you’re looking to upgrade existing equipment or design a new system, this fan can deliver the cooling power you need in a way that blends seamlessly into your space.
In summary, the DC Axial Compact Fan 4412 FGM is a versatile and reliable cooling solution suitable for a variety of electronic and industrial applications. Its compact size, efficient performance, and reliable operation make it an excellent choice for anyone who needs powerful cooling in a limited space. Upgrade your equipment with the DC Axial Compact Fan 4412 FGM and experience the benefits of reliable, efficient cooling in a compact package.
What’s the maximum voltage you can apply to a blower?
The maximum voltage that can be applied to a fan motor varies from model to model, but is typically 5%-10% above the nominal voltage listed. Consult the factory to determine the maximum voltage for a particular part number, and to learn more about the negative effects that high voltages might have on the motor
What is a fan’s of voltage range?
Ebmpapst EC fans are able to perform equally well across a range of input voltages. These fans will have the maximum and minimum acceptable voltages listed on the label, such as the one below:
Note that in order to reach a desired performance point, the fan may need to draw additional current at low voltages.
Can all 60 Hz blower motors operate on a frequency of 50 Hz?
Not all ebmpapst fans are designed to operate at both 50 and 60 Hz. If a fan is able to accept both 50 Hz and 60 Hz power supplies, it will have a “50/60Hz” mark on its label, such as the one below:
Consult the factory if you intend to use a power supply with a frequency that does not match the recommended frequency of your fan.
When determining fan performance, several factors are taken into consideration. These factors primarily include: airflow, static pressure, operating points, RPM, power & current, and sound performance. Of these factors, ebmpapst presents a performance curve with our products to provide a quick-glance overview of the performance. Performance curves use just three of the aforementioned factors: airflow, static pressure, and operating points.
What is Airflow?
For the air-moving industry, it is important to know how quickly some volume of air is being displaced from one location to another, or, more simply stated, how much air is being moved in a set amount of time.
Ebmpapst typically expresses airflow in Cubic Feet per Minute (CFM) or cubic meters per hour (m3/h).
What is Static Pressure?
Once again the air-moving industry is faced with another challenge, the resistance to flow. Static pressure, sometimes referred to as back pressure or system resistance, is a continuous force on the air (or gas) due to the resistance to flow. These resistances to flow can come from sources such as static air, turbulence and impedances within the system like filters or grills. A higher static pressure will cause a lower airflow, in the same way that a smaller pipe reduces the amount of water that can flow through it.
Ebmpapst typically expresses static pressure in inches water gauge (in. W.G.) or Pascals (Pa).
What is the System Operating Point?
For any fan we can determine how much air it is able to move in a given amount of time (airflow) and how much static pressure it can overcome. For any given system, we can determine the amount of static pressure it will create at any given airflow.
Taking these known values for airflow and static pressure, we can plot them on a two-dimensional chart. The operating point is the point at which the fan performance curve and the system resistance curve intersect. In real terms, it is the amount of airflow a given fan can move through a given system.
How do I read an air performance curve?
To aid in fan selection, ebmpapst provides an air performance graph with its products. The air performance graph consists of a series of curves that chart airflow against static pressure.
Follow along on the chart below. The x-axis is for airflow, while the y-axis is for static pressure. The blue line ‘A’ illustrates the fan’s performance outside of a system. To find the operating point 900CFM @ 2 in.w.g., follow the x-axis to 900, then follow the y-axis up to 2 (Point ‘B’). Since this operating point ‘B’ is below the performance curve, it is a point that the fan can achieve.
Lines ‘C’, ‘D’, and ‘E’ are example system resistance curves – as airflow increases, the static pressure (or resistance to airflow) also increases, making it harder to move air. Typically, any point between the highest and lowest of our example resistance curves is the ideal operating range for the fan to achieve its highest efficiency. Some performance graphs will have multiple airflow curves; this would indicate that the fan is capable of multiple speeds in order to match operating points below its maximum speed, thus saving energy.
Forward Curved Impellers
- There are two types of forward curved impellers, dual and single inlet.
- Used primarily in medium pressure, high flow applications.
- Possible market uses: ventilation, refrigeration etc.
Backward Curved Impellers
- Used primarily in high pressure, high flow applications.
- Possible market uses: data center, general ventilation, agriculture; transportation etc.
Axial Fans
- Used primarily in low pressure, high flow applications.
- Possible market uses: LED, ventilation, agriculture; transportation, etc.