AC centrifugal fan-D2E146-HR93-01

Short Description:

forward curved, dual inlet

AC Centrifugal Blower, 146mm, 230VAC, 205CFM

Introducing the EBM Blower AC Centrifugal Fan, Dual Inlet D2E146-HR93-01, the latest innovation in the AC Centrifugal Blower series. This blower boasts a forward-curved design and a 146mm diameter, making it suitable for a wide range of applications. With a voltage of 230VAC, it delivers high-quality performance with a maximum output airflow of 205CFM.


Product Detail

Product Tags

FAQ

Introducing

Designed to meet the needs of various industries, this dual inlet AC Centrifugal Blower operates at a low noise level, ensuring an uninterrupted working environment. The blower's dual inlet feature allows for superior cooling, while also reducing noise levels further. With a robust build and high efficiency, it is the ideal choice for equipment that operates in high temperatures, ensuring longevity and reliability.

This blower is perfect for use in air conditioning units, ventilation systems, and heat exchangers, where it provides excellent airflow and reliable performance. Furthermore, it can also be used for cooling electronics, such as computers and servers, where it ensures optimal temperature control for maximum efficiency. The blower's compact shape and easy to install design make it ideal for use in smaller spaces, where its high performance ensures long-lasting, reliable operation.

The EBM Blower AC Centrifugal Fan, Dual Inlet D2E146-HR93-01 is built to last, with a strong and durable design to handle the rigors of daily use. Its high-quality construction ensures that it can withstand high temperatures, dust, and moisture, making it an ideal choice for challenging environments. With its state-of-the-art engineering, this blower is energy-efficient, helping to reduce operational costs and promote sustainable practices.

In conclusion, the EBM Blower AC Centrifugal Fan, Dual Inlet D2E146-HR93-01 is an excellent choice for any industry that needs a reliable and high-performing AC centrifugal blower. Its forward-curved design, dual inlet feature, and high airflow make it perfect for a wide range of applications. With its robust build and energy-efficient operation, this blower is designed to provide top-quality performance and durability for years to come. Choose the EBM Blower AC Centrifugal Fan, Dual Inlet D2E146-HR93-01 for a reliable and efficient solution for all your air cooling and ventilation needs.


  • Previous:
  • Next:

  • What motors does Lianxing offer?
    Do you have a minimum order quantity?

    What’s the maximum voltage you can apply to a blower?
    The maximum voltage that can be applied to a fan motor varies from model to model, but is typically 5%-10% above the nominal voltage listed.  Consult the factory to determine the maximum voltage for a particular part number, and to learn more about the negative effects that high voltages might have on the motor

    What is a fan’s of voltage range?
    Ebmpapst EC fans are able to perform equally well across a range of input voltages. These fans will have the maximum and minimum acceptable voltages listed on the label, such as the one below:

     detail3 

    Note that in order to reach a desired performance point, the fan may need to draw additional current at low voltages.

    Can all 60 Hz blower motors operate on a frequency of 50 Hz?
    Not all ebmpapst fans are designed to operate at both 50 and 60 Hz. If a fan is able to accept both 50 Hz and 60 Hz power supplies, it will have a “50/60Hz” mark on its label, such as the one below:

     detail2

    Consult the factory if you intend to use a power supply with a frequency that does not match the recommended frequency of your fan.

    How is fan performance defined?

    When determining fan performance, several factors are taken into consideration. These factors primarily include: airflow, static pressure, operating points, RPM, power & current, and sound performance. Of these factors, ebmpapst presents a performance curve with our products to provide a quick-glance overview of the performance. Performance curves use just three of the aforementioned factors: airflow, static pressure, and operating points.

    What is Airflow?
    For the air-moving industry, it is important to know how quickly some volume of air is being displaced from one location to another, or, more simply stated, how much air is being moved in a set amount of time.

    Ebmpapst typically expresses airflow in Cubic Feet per Minute (CFM) or cubic meters per hour (m3/h).


    What is Static Pressure?
    Once again the air-moving industry is faced with another challenge, the resistance to flow. Static pressure, sometimes referred to as back pressure or system resistance, is a continuous force on the air (or gas) due to the resistance to flow. These resistances to flow can come from sources such as static air, turbulence and impedances within the system like filters or grills. A higher static pressure will cause a lower airflow, in the same way that a smaller pipe reduces the amount of water that can flow through it.

    Ebmpapst typically expresses static pressure in inches water gauge (in. W.G.) or Pascals (Pa).


    What is the System Operating Point?
    For any fan we can determine how much air it is able to move in a given amount of time (airflow) and how much static pressure it can overcome. For any given system, we can determine the amount of static pressure it will create at any given airflow.

    Taking these known values for airflow and static pressure, we can plot them on a two-dimensional chart. The operating point is the point at which the fan performance curve and the system resistance curve intersect. In real terms, it is the amount of airflow a given fan can move through a given system.


    How do I read an air performance curve?
    To aid in fan selection, ebmpapst provides an air performance graph with its products. The air performance graph consists of a series of curves that chart airflow against static pressure.

    Follow along on the chart below. The x-axis is for airflow, while the y-axis is for static pressure. The blue line ‘A’ illustrates the fan’s performance outside of a system. To find the operating point 900CFM @ 2 in.w.g., follow the x-axis to 900, then follow the y-axis up to 2 (Point ‘B’). Since this operating point ‘B’ is below the performance curve, it is a point that the fan can achieve.

    detail1

    Lines ‘C’, ‘D’, and ‘E’ are example system resistance curves – as airflow increases, the static pressure (or resistance to airflow) also increases, making it harder to move air. Typically, any point between the highest and lowest of our example resistance curves is the ideal operating range for the fan to achieve its highest efficiency. Some performance graphs will have multiple airflow curves; this would indicate that the fan is capable of multiple speeds in order to match operating points below its maximum speed, thus saving energy.

    What types of produces does ebmpapst make? What is each type best suited for ?

     Forward Curved Impellers

    detail4 

    • There are two types of forward curved impellers, dual and single inlet.
    • Used primarily in medium pressure, high flow applications.
    • Possible market uses: ventilation, refrigeration etc.

    Backward Curved Impellers

    detail5

    • Used primarily in high pressure, high flow applications.
    • Possible market uses: data center, general ventilation, agriculture; transportation etc.

    Axial Fans

    3

    • Used primarily in low pressure, high flow applications.
    • Possible market uses: LED, ventilation, agriculture; transportation, etc.