To frequently enhance the management process by virtue of your rule of “sincerely, good religion and good quality are the base of company development”, we greatly absorb the essence of associated solutions internationally, and regularly produce new goods to meet the needs of shoppers for 2019 High quality Original Axial fan W2S130-AA03-90 45W 115V Dual voltage fan, With a quickly enhancement and our customers come from Europe, United States, Africa and everywhere in the world. Welcome to go to our manufacturing unit and welcome your get, for more inquires be sure to never hesitate to get in touch with us!
To frequently enhance the management process by virtue of your rule of “sincerely, good religion and good quality are the base of company development”, we greatly absorb the essence of associated solutions internationally, and regularly produce new goods to meet the needs of shoppers for , Due to good quality and reasonable prices, our items have been exported to more than 10 countries and regions. We have been looking forward to cooperating with all customers from at home and abroad. Moreover, customer satisfaction is our eternal pursuit.
Nominal data
Introducing
This fan is powered by 230VAC and produces an impressive airflow of 223.6CFM, ensuring that your device remains cool even during intense usage. With a power rating of 39W, it provides enough power to keep your device running optimally without generating excessive heat. What’s more, this fan operates at a low noise level of 53dBA, ensuring that it doesn’t disturb your work or relaxation.
The AC axial compact fan features a ball bearing system that ensures quiet and long-lasting operation. With 3250RPM, it will keep your device well-ventilated without producing excessive noise. The ball bearings provide the fan with stability while reducing friction, reducing the risk of damage to the system.
Installing the AC axial compact fan – W2S130-AA03-01 can be done quickly and easily. The fan is designed to be mounted on the device’s enclosure, providing an efficient cooling solution that optimizes your device’s performance. The fan is also easy to maintain, ensuring that it works optimally without downtime.
In conclusion, if you’re looking for an axial fan that delivers powerful performance, the AC axial compact fan – W2S130-AA03-01 is an excellent choice. It provides reliable and efficient cooling for all your devices, ensuring that they remain cool and run optimally. With ball bearing technology, low noise levels, and easy installation, this fan provides the perfect balance between performance and functionality. Get yours today and take your device’s performance to the next level.
To frequently enhance the management process by virtue of your rule of “sincerely, good religion and good quality are the base of company development”, we greatly absorb the essence of associated solutions internationally, and regularly produce new goods to meet the needs of shoppers for 2019 High quality Original Axial fan W2S130-AA03-90 45W 115V Dual voltage fan, With a quickly enhancement and our customers come from Europe, United States, Africa and everywhere in the world. Welcome to go to our manufacturing unit and welcome your get, for more inquires be sure to never hesitate to get in touch with us!
2019 High quality , Due to good quality and reasonable prices, our items have been exported to more than 10 countries and regions. We have been looking forward to cooperating with all customers from at home and abroad. Moreover, customer satisfaction is our eternal pursuit.
What’s the maximum voltage you can apply to a blower?
The maximum voltage that can be applied to a fan motor varies from model to model, but is typically 5%-10% above the nominal voltage listed. Consult the factory to determine the maximum voltage for a particular part number, and to learn more about the negative effects that high voltages might have on the motor
What is a fan’s of voltage range?
Ebmpapst EC fans are able to perform equally well across a range of input voltages. These fans will have the maximum and minimum acceptable voltages listed on the label, such as the one below:
Note that in order to reach a desired performance point, the fan may need to draw additional current at low voltages.
Can all 60 Hz blower motors operate on a frequency of 50 Hz?
Not all ebmpapst fans are designed to operate at both 50 and 60 Hz. If a fan is able to accept both 50 Hz and 60 Hz power supplies, it will have a “50/60Hz” mark on its label, such as the one below:
Consult the factory if you intend to use a power supply with a frequency that does not match the recommended frequency of your fan.
When determining fan performance, several factors are taken into consideration. These factors primarily include: airflow, static pressure, operating points, RPM, power & current, and sound performance. Of these factors, ebmpapst presents a performance curve with our products to provide a quick-glance overview of the performance. Performance curves use just three of the aforementioned factors: airflow, static pressure, and operating points.
What is Airflow?
For the air-moving industry, it is important to know how quickly some volume of air is being displaced from one location to another, or, more simply stated, how much air is being moved in a set amount of time.
Ebmpapst typically expresses airflow in Cubic Feet per Minute (CFM) or cubic meters per hour (m3/h).
What is Static Pressure?
Once again the air-moving industry is faced with another challenge, the resistance to flow. Static pressure, sometimes referred to as back pressure or system resistance, is a continuous force on the air (or gas) due to the resistance to flow. These resistances to flow can come from sources such as static air, turbulence and impedances within the system like filters or grills. A higher static pressure will cause a lower airflow, in the same way that a smaller pipe reduces the amount of water that can flow through it.
Ebmpapst typically expresses static pressure in inches water gauge (in. W.G.) or Pascals (Pa).
What is the System Operating Point?
For any fan we can determine how much air it is able to move in a given amount of time (airflow) and how much static pressure it can overcome. For any given system, we can determine the amount of static pressure it will create at any given airflow.
Taking these known values for airflow and static pressure, we can plot them on a two-dimensional chart. The operating point is the point at which the fan performance curve and the system resistance curve intersect. In real terms, it is the amount of airflow a given fan can move through a given system.
How do I read an air performance curve?
To aid in fan selection, ebmpapst provides an air performance graph with its products. The air performance graph consists of a series of curves that chart airflow against static pressure.
Follow along on the chart below. The x-axis is for airflow, while the y-axis is for static pressure. The blue line ‘A’ illustrates the fan’s performance outside of a system. To find the operating point 900CFM @ 2 in.w.g., follow the x-axis to 900, then follow the y-axis up to 2 (Point ‘B’). Since this operating point ‘B’ is below the performance curve, it is a point that the fan can achieve.
Lines ‘C’, ‘D’, and ‘E’ are example system resistance curves – as airflow increases, the static pressure (or resistance to airflow) also increases, making it harder to move air. Typically, any point between the highest and lowest of our example resistance curves is the ideal operating range for the fan to achieve its highest efficiency. Some performance graphs will have multiple airflow curves; this would indicate that the fan is capable of multiple speeds in order to match operating points below its maximum speed, thus saving energy.
Forward Curved Impellers
- There are two types of forward curved impellers, dual and single inlet.
- Used primarily in medium pressure, high flow applications.
- Possible market uses: ventilation, refrigeration etc.
Backward Curved Impellers
- Used primarily in high pressure, high flow applications.
- Possible market uses: data center, general ventilation, agriculture; transportation etc.
Axial Fans
- Used primarily in low pressure, high flow applications.
- Possible market uses: LED, ventilation, agriculture; transportation, etc.